{"id":647,"date":"2013-06-24T13:15:45","date_gmt":"2013-06-24T20:15:45","guid":{"rendered":"http:\/\/www.rbdinstruments.com\/blog\/?p=647"},"modified":"2014-11-06T09:19:47","modified_gmt":"2014-11-06T17:19:47","slug":"removing-oil-from-a-turbo-pump","status":"publish","type":"post","link":"https:\/\/www.rbdinstruments.com\/blog\/removing-oil-from-a-turbo-pump\/","title":{"rendered":"Removing oil from a turbo pump"},"content":{"rendered":"<p>This post will explain the procedure for removing oil from a turbo pump if the vent valve failed and oil was sucked up into the blades.<\/p>\n<p>Under normal conditions, when an oil rotary vane mechanical backed turbo pump is turned off it should be vented (preferably with dry nitrogen) to prevent the back streaming of oil or oil vapors onto the turbo pump blades. Sometimes the vent valve will fail, or some other mishap can lead to oil being sucked up the roughing line from the mechanical pump into the turbo pump. When this happens, the symptoms are that the pump will not come up to full speed \u2013 usually only 50% to 75%. Or, sometimes the pump will come up to full speed (barely) but the pumping\u00a0efficiency has been greatly reduced.<\/p>\n<p>For Balzers turbo pumps, the procedure is to pull the turbo pump and place it in a beaker of isopropanol up to the bottom of the inlet as shown in the picture below. For other turbo pumps the procedure is probably similar, but you should check the turbo pump manual to be sure. NOTE: This procedure is only for turbo pumps that have a magnetic bearing on the front end.<\/p>\n<div id=\"attachment_648\" style=\"width: 474px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-oil.jpg?ssl=1\"><img aria-describedby=\"caption-attachment-648\" data-attachment-id=\"648\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/removing-oil-from-a-turbo-pump\/turbo-pump-oil\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-oil.jpg?fit=464%2C337&amp;ssl=1\" data-orig-size=\"464,337\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"turbo pump oil\" data-image-description=\"\" data-image-caption=\"\" data-medium-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-oil.jpg?fit=300%2C217&amp;ssl=1\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-oil.jpg?fit=464%2C337&amp;ssl=1\" decoding=\"async\" loading=\"lazy\" class=\"lazy size-full wp-image-648\" title=\"Max fill height\" alt=\"turbo pump oil\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/plugins\/jquery-image-lazy-loading\/images\/grey.gif?resize=464%2C337&#038;ssl=1\" data-original=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-oil.jpg\" width=\"464\" height=\"337\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-oil.jpg?w=464&amp;ssl=1 464w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-oil.jpg?resize=300%2C217&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-oil.jpg?resize=413%2C300&amp;ssl=1 413w\" sizes=\"(max-width: 464px) 100vw, 464px\" data-recalc-dims=\"1\" \/><p id=\"caption-attachment-648\" class=\"wp-caption-text\"><noscript><img data-attachment-id=\"648\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/removing-oil-from-a-turbo-pump\/turbo-pump-oil\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-oil.jpg?fit=464%2C337&amp;ssl=1\" data-orig-size=\"464,337\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"turbo pump oil\" data-image-description=\"\" data-image-caption=\"\" data-medium-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-oil.jpg?fit=300%2C217&amp;ssl=1\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-oil.jpg?fit=464%2C337&amp;ssl=1\" decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-648\" title=\"Max fill height\" alt=\"turbo pump oil\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-oil.jpg?resize=464%2C337&#038;ssl=1\" width=\"464\" height=\"337\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-oil.jpg?w=464&amp;ssl=1 464w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-oil.jpg?resize=300%2C217&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-oil.jpg?resize=413%2C300&amp;ssl=1 413w\" sizes=\"(max-width: 464px) 100vw, 464px\" data-recalc-dims=\"1\" \/><\/noscript><\/a> Turbo pump shown upside down in container &#8211; motor is on top.<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>If you fill the container higher than the inlet shown in the picture above then you will get isopropanol into the motor (not good). \u00a0Let the turbo sit in the isopropanol for a few minutes and then move the turbo up and down a little bit to help remove more oil from the blades. Remove the turbo and if the isopropanol is yellow from the oil, discard the isopropanol (in the appropriate container so that it can be disposed of properly) and repeat.<\/p>\n<p>Once the turbo is clean, remove it and place it on some Kim wipes or paper towels and let it dry thoroughly. Note that in the original Balzers procedure that Freon TF was used. Isopropanol has similar degreasing properties and is not nearly as bad for the environment.<\/p>\n<p>As long as you have the turbo pump out, you should check the condition the bottom bearing. Remove the plug and inspect the felt washer or washer assembly. Clean or replace as needed.<\/p>\n<p>Once the turbo pump is dry, it should be good to go.<\/p>\n<p>You can also use isopropanol to clean the rough lines that go from the mechanical pump to the turbo pump.<\/p>\n\n\t\t<style type=\"text\/css\">\n\t\t\t#gallery-1 {\n\t\t\t\tmargin: auto;\n\t\t\t}\n\t\t\t#gallery-1 .gallery-item {\n\t\t\t\tfloat: left;\n\t\t\t\tmargin-top: 10px;\n\t\t\t\ttext-align: center;\n\t\t\t\twidth: 33%;\n\t\t\t}\n\t\t\t#gallery-1 img {\n\t\t\t\tborder: 2px solid #cfcfcf;\n\t\t\t}\n\t\t\t#gallery-1 .gallery-caption {\n\t\t\t\tmargin-left: 0;\n\t\t\t}\n\t\t\t\/* see gallery_shortcode() in wp-includes\/media.php *\/\n\t\t<\/style>\n\t\t<div data-carousel-extra='{\"blog_id\":1,\"permalink\":\"https:\\\/\\\/www.rbdinstruments.com\\\/blog\\\/removing-oil-from-a-turbo-pump\\\/\"}' id='gallery-1' class='gallery galleryid-647 gallery-columns-3 gallery-size-thumbnail'><dl class='gallery-item'>\n\t\t\t<dt class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/www.rbdinstruments.com\/blog\/removing-oil-from-a-turbo-pump\/turbo-pump-contaminated-with-oil\/'><img width=\"150\" height=\"150\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/plugins\/jquery-image-lazy-loading\/images\/grey.gif?resize=150%2C150&#038;ssl=1\" data-original=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-contaminated-with-oil.jpg?resize=150%2C150&amp;ssl=1\" class=\"lazy attachment-thumbnail size-thumbnail\" alt=\"\" decoding=\"async\" aria-describedby=\"gallery-1-652\" loading=\"lazy\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-contaminated-with-oil.jpg?resize=150%2C150&amp;ssl=1 150w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-contaminated-with-oil.jpg?zoom=2&amp;resize=150%2C150&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-contaminated-with-oil.jpg?zoom=3&amp;resize=150%2C150&amp;ssl=1 450w\" sizes=\"(max-width: 150px) 100vw, 150px\" data-attachment-id=\"652\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/removing-oil-from-a-turbo-pump\/turbo-pump-contaminated-with-oil\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-contaminated-with-oil.jpg?fit=486%2C324&amp;ssl=1\" data-orig-size=\"486,324\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;5&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;Canon EOS DIGITAL REBEL XTi&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1370940604&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;65&quot;,&quot;iso&quot;:&quot;400&quot;,&quot;shutter_speed&quot;:&quot;0.016666666666667&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"turbo pump contaminated with oil\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;oil contaminated turbo pump&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-contaminated-with-oil.jpg?fit=300%2C200&amp;ssl=1\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-contaminated-with-oil.jpg?fit=486%2C324&amp;ssl=1\" data-recalc-dims=\"1\" \/><noscript><img width=\"150\" height=\"150\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-contaminated-with-oil.jpg?resize=150%2C150&amp;ssl=1\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" decoding=\"async\" aria-describedby=\"gallery-1-652\" loading=\"lazy\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-contaminated-with-oil.jpg?resize=150%2C150&amp;ssl=1 150w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-contaminated-with-oil.jpg?zoom=2&amp;resize=150%2C150&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-contaminated-with-oil.jpg?zoom=3&amp;resize=150%2C150&amp;ssl=1 450w\" sizes=\"(max-width: 150px) 100vw, 150px\" data-attachment-id=\"652\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/removing-oil-from-a-turbo-pump\/turbo-pump-contaminated-with-oil\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-contaminated-with-oil.jpg?fit=486%2C324&amp;ssl=1\" data-orig-size=\"486,324\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;5&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;Canon EOS DIGITAL REBEL XTi&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1370940604&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;65&quot;,&quot;iso&quot;:&quot;400&quot;,&quot;shutter_speed&quot;:&quot;0.016666666666667&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"turbo pump contaminated with oil\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;oil contaminated turbo pump&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-contaminated-with-oil.jpg?fit=300%2C200&amp;ssl=1\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-contaminated-with-oil.jpg?fit=486%2C324&amp;ssl=1\" \/><\/noscript><\/a>\n\t\t\t<\/dt>\n\t\t\t\t<dd class='wp-caption-text gallery-caption' id='gallery-1-652'>\n\t\t\t\toil contaminated turbo pump\n\t\t\t\t<\/dd><\/dl><dl class='gallery-item'>\n\t\t\t<dt class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/www.rbdinstruments.com\/blog\/removing-oil-from-a-turbo-pump\/place-turbo-pump-in-container\/'><img width=\"150\" height=\"150\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/plugins\/jquery-image-lazy-loading\/images\/grey.gif?resize=150%2C150&#038;ssl=1\" data-original=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/place-turbo-pump-in-container.jpg?resize=150%2C150&amp;ssl=1\" class=\"lazy attachment-thumbnail size-thumbnail\" alt=\"\" decoding=\"async\" aria-describedby=\"gallery-1-651\" loading=\"lazy\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/place-turbo-pump-in-container.jpg?resize=150%2C150&amp;ssl=1 150w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/place-turbo-pump-in-container.jpg?zoom=2&amp;resize=150%2C150&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/place-turbo-pump-in-container.jpg?zoom=3&amp;resize=150%2C150&amp;ssl=1 450w\" sizes=\"(max-width: 150px) 100vw, 150px\" data-attachment-id=\"651\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/removing-oil-from-a-turbo-pump\/place-turbo-pump-in-container\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/place-turbo-pump-in-container.jpg?fit=486%2C324&amp;ssl=1\" data-orig-size=\"486,324\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;4&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;Canon EOS DIGITAL REBEL XTi&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1370940613&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;44&quot;,&quot;iso&quot;:&quot;400&quot;,&quot;shutter_speed&quot;:&quot;0.016666666666667&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"place turbo pump in container\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;place turbo pump into container&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/place-turbo-pump-in-container.jpg?fit=300%2C200&amp;ssl=1\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/place-turbo-pump-in-container.jpg?fit=486%2C324&amp;ssl=1\" data-recalc-dims=\"1\" \/><noscript><img width=\"150\" height=\"150\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/place-turbo-pump-in-container.jpg?resize=150%2C150&amp;ssl=1\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" decoding=\"async\" aria-describedby=\"gallery-1-651\" loading=\"lazy\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/place-turbo-pump-in-container.jpg?resize=150%2C150&amp;ssl=1 150w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/place-turbo-pump-in-container.jpg?zoom=2&amp;resize=150%2C150&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/place-turbo-pump-in-container.jpg?zoom=3&amp;resize=150%2C150&amp;ssl=1 450w\" sizes=\"(max-width: 150px) 100vw, 150px\" data-attachment-id=\"651\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/removing-oil-from-a-turbo-pump\/place-turbo-pump-in-container\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/place-turbo-pump-in-container.jpg?fit=486%2C324&amp;ssl=1\" data-orig-size=\"486,324\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;4&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;Canon EOS DIGITAL REBEL XTi&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1370940613&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;44&quot;,&quot;iso&quot;:&quot;400&quot;,&quot;shutter_speed&quot;:&quot;0.016666666666667&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"place turbo pump in container\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;place turbo pump into container&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/place-turbo-pump-in-container.jpg?fit=300%2C200&amp;ssl=1\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/place-turbo-pump-in-container.jpg?fit=486%2C324&amp;ssl=1\" \/><\/noscript><\/a>\n\t\t\t<\/dt>\n\t\t\t\t<dd class='wp-caption-text gallery-caption' id='gallery-1-651'>\n\t\t\t\tplace turbo pump into container\n\t\t\t\t<\/dd><\/dl><dl class='gallery-item'>\n\t\t\t<dt class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/www.rbdinstruments.com\/blog\/removing-oil-from-a-turbo-pump\/add-isopropanol-to-container\/'><img width=\"150\" height=\"150\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/plugins\/jquery-image-lazy-loading\/images\/grey.gif?resize=150%2C150&#038;ssl=1\" data-original=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/add-isopropanol-to-container.jpg?resize=150%2C150&amp;ssl=1\" class=\"lazy attachment-thumbnail size-thumbnail\" alt=\"\" decoding=\"async\" aria-describedby=\"gallery-1-650\" loading=\"lazy\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/add-isopropanol-to-container.jpg?resize=150%2C150&amp;ssl=1 150w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/add-isopropanol-to-container.jpg?zoom=2&amp;resize=150%2C150&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/add-isopropanol-to-container.jpg?zoom=3&amp;resize=150%2C150&amp;ssl=1 450w\" sizes=\"(max-width: 150px) 100vw, 150px\" data-attachment-id=\"650\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/removing-oil-from-a-turbo-pump\/add-isopropanol-to-container\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/add-isopropanol-to-container.jpg?fit=486%2C324&amp;ssl=1\" data-orig-size=\"486,324\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;4&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;Canon EOS DIGITAL REBEL XTi&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1370940638&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;38&quot;,&quot;iso&quot;:&quot;400&quot;,&quot;shutter_speed&quot;:&quot;0.016666666666667&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"add isopropanol to container\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;pour isopropanol into container&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/add-isopropanol-to-container.jpg?fit=300%2C200&amp;ssl=1\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/add-isopropanol-to-container.jpg?fit=486%2C324&amp;ssl=1\" data-recalc-dims=\"1\" \/><noscript><img width=\"150\" height=\"150\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/add-isopropanol-to-container.jpg?resize=150%2C150&amp;ssl=1\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" decoding=\"async\" aria-describedby=\"gallery-1-650\" loading=\"lazy\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/add-isopropanol-to-container.jpg?resize=150%2C150&amp;ssl=1 150w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/add-isopropanol-to-container.jpg?zoom=2&amp;resize=150%2C150&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/add-isopropanol-to-container.jpg?zoom=3&amp;resize=150%2C150&amp;ssl=1 450w\" sizes=\"(max-width: 150px) 100vw, 150px\" data-attachment-id=\"650\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/removing-oil-from-a-turbo-pump\/add-isopropanol-to-container\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/add-isopropanol-to-container.jpg?fit=486%2C324&amp;ssl=1\" data-orig-size=\"486,324\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;4&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;Canon EOS DIGITAL REBEL XTi&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1370940638&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;38&quot;,&quot;iso&quot;:&quot;400&quot;,&quot;shutter_speed&quot;:&quot;0.016666666666667&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"add isopropanol to container\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;pour isopropanol into container&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/add-isopropanol-to-container.jpg?fit=300%2C200&amp;ssl=1\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/add-isopropanol-to-container.jpg?fit=486%2C324&amp;ssl=1\" \/><\/noscript><\/a>\n\t\t\t<\/dt>\n\t\t\t\t<dd class='wp-caption-text gallery-caption' id='gallery-1-650'>\n\t\t\t\tpour isopropanol into container\n\t\t\t\t<\/dd><\/dl><br style=\"clear: both\" \/><dl class='gallery-item'>\n\t\t\t<dt class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/www.rbdinstruments.com\/blog\/removing-oil-from-a-turbo-pump\/oil-contaminated-isopropanol\/'><img width=\"150\" height=\"150\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/plugins\/jquery-image-lazy-loading\/images\/grey.gif?resize=150%2C150&#038;ssl=1\" data-original=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/oil-contaminated-isopropanol.jpg?resize=150%2C150&amp;ssl=1\" class=\"lazy attachment-thumbnail size-thumbnail\" alt=\"\" decoding=\"async\" aria-describedby=\"gallery-1-649\" loading=\"lazy\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/oil-contaminated-isopropanol.jpg?resize=150%2C150&amp;ssl=1 150w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/oil-contaminated-isopropanol.jpg?zoom=2&amp;resize=150%2C150&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/oil-contaminated-isopropanol.jpg?zoom=3&amp;resize=150%2C150&amp;ssl=1 450w\" sizes=\"(max-width: 150px) 100vw, 150px\" data-attachment-id=\"649\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/removing-oil-from-a-turbo-pump\/oil-contaminated-isopropanol\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/oil-contaminated-isopropanol.jpg?fit=486%2C324&amp;ssl=1\" data-orig-size=\"486,324\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;4&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;Canon EOS DIGITAL REBEL XTi&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1370945915&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;28&quot;,&quot;iso&quot;:&quot;400&quot;,&quot;shutter_speed&quot;:&quot;0.016666666666667&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"oil contaminated isopropanol\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;oil contaminated isopropanol&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/oil-contaminated-isopropanol.jpg?fit=300%2C200&amp;ssl=1\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/oil-contaminated-isopropanol.jpg?fit=486%2C324&amp;ssl=1\" data-recalc-dims=\"1\" \/><noscript><img width=\"150\" height=\"150\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/oil-contaminated-isopropanol.jpg?resize=150%2C150&amp;ssl=1\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" decoding=\"async\" aria-describedby=\"gallery-1-649\" loading=\"lazy\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/oil-contaminated-isopropanol.jpg?resize=150%2C150&amp;ssl=1 150w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/oil-contaminated-isopropanol.jpg?zoom=2&amp;resize=150%2C150&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/oil-contaminated-isopropanol.jpg?zoom=3&amp;resize=150%2C150&amp;ssl=1 450w\" sizes=\"(max-width: 150px) 100vw, 150px\" data-attachment-id=\"649\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/removing-oil-from-a-turbo-pump\/oil-contaminated-isopropanol\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/oil-contaminated-isopropanol.jpg?fit=486%2C324&amp;ssl=1\" data-orig-size=\"486,324\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;4&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;Canon EOS DIGITAL REBEL XTi&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1370945915&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;28&quot;,&quot;iso&quot;:&quot;400&quot;,&quot;shutter_speed&quot;:&quot;0.016666666666667&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"oil contaminated isopropanol\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;oil contaminated isopropanol&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/oil-contaminated-isopropanol.jpg?fit=300%2C200&amp;ssl=1\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/oil-contaminated-isopropanol.jpg?fit=486%2C324&amp;ssl=1\" \/><\/noscript><\/a>\n\t\t\t<\/dt>\n\t\t\t\t<dd class='wp-caption-text gallery-caption' id='gallery-1-649'>\n\t\t\t\toil contaminated isopropanol\n\t\t\t\t<\/dd><\/dl>\n\t\t\t<br style='clear: both' \/>\n\t\t<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>This post will explain the procedure for removing oil from a turbo pump if the vent valve failed and oil was sucked up into the blades. Under normal conditions, when an oil rotary vane mechanical backed turbo pump is turned &hellip; <a href=\"https:\/\/www.rbdinstruments.com\/blog\/removing-oil-from-a-turbo-pump\/\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":648,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","footnotes":"","jetpack_publicize_message":"","jetpack_is_tweetstorm":false,"jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false}}},"categories":[164],"tags":[93,16],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/06\/turbo-pump-oil.jpg?fit=464%2C337&ssl=1","jetpack_shortlink":"https:\/\/wp.me\/p2DEXo-ar","jetpack_sharing_enabled":true,"jetpack_likes_enabled":true,"jetpack-related-posts":[{"id":2388,"url":"https:\/\/www.rbdinstruments.com\/blog\/avc-up-to-air-relay-update\/","url_meta":{"origin":647,"position":0},"title":"AVC Up to Air relay update","author":"Randy","date":"July 31, 2018","format":false,"excerpt":"The Auto Valve Controller (AVC) is used to open and close valves on PHI surface analysis systems such as the 5000 series XPS and 660 scanning Auger systems.\u00a0 The AVC has a small built in microprocessor and so it also has the ability to protect the user from inadvertently opening\u2026","rel":"","context":"In &quot;Operation and Calibration Procedures&quot;","block_context":{"text":"Operation and Calibration Procedures","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/operation-and-calibration-procedures\/"},"img":{"alt_text":"Up to Air relay inside AVC","src":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2018\/07\/Up-to-Air-relay-inside-AVC.jpg?fit=1200%2C900&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2018\/07\/Up-to-Air-relay-inside-AVC.jpg?fit=1200%2C900&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2018\/07\/Up-to-Air-relay-inside-AVC.jpg?fit=1200%2C900&ssl=1&resize=700%2C400 2x, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2018\/07\/Up-to-Air-relay-inside-AVC.jpg?fit=1200%2C900&ssl=1&resize=1050%2C600 3x"},"classes":[]},{"id":3501,"url":"https:\/\/www.rbdinstruments.com\/blog\/avc-auto-valve-controller-theory-and-operation\/","url_meta":{"origin":647,"position":1},"title":"AVC Auto Valve Controller Theory and Operation","author":"Randy","date":"February 15, 2022","format":false,"excerpt":"Theory and operation of Auto Valve controller (AVC) used on older Physical Electronics surface analysis systems.","rel":"","context":"In &quot;Operation and Calibration Procedures&quot;","block_context":{"text":"Operation and Calibration Procedures","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/operation-and-calibration-procedures\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2022\/02\/AVC-controller.jpg?fit=1200%2C1200&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2022\/02\/AVC-controller.jpg?fit=1200%2C1200&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2022\/02\/AVC-controller.jpg?fit=1200%2C1200&ssl=1&resize=700%2C400 2x, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2022\/02\/AVC-controller.jpg?fit=1200%2C1200&ssl=1&resize=1050%2C600 3x"},"classes":[]},{"id":1548,"url":"https:\/\/www.rbdinstruments.com\/blog\/up-to-air\/","url_meta":{"origin":647,"position":2},"title":"660 System up to air procedure","author":"Randy","date":"August 5, 2015","format":false,"excerpt":"Overview This procedure will allow you to safely bring the 660 scanning auger system up to air for maintenance. \u00a0 Shut down AugerMap and turn off the 20-610 electron gun control (filament down slowly) Also turn off the 20-622 gun control. Turn off the card rack power If V4 is\u2026","rel":"","context":"In &quot;General Optics and Vacuum&quot;","block_context":{"text":"General Optics and Vacuum","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/general-optics-and-vacuum\/"},"img":{"alt_text":"phi-660-scanning-auger","src":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2015\/08\/SAM660.jpg?fit=1200%2C900&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2015\/08\/SAM660.jpg?fit=1200%2C900&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2015\/08\/SAM660.jpg?fit=1200%2C900&ssl=1&resize=700%2C400 2x, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2015\/08\/SAM660.jpg?fit=1200%2C900&ssl=1&resize=1050%2C600 3x"},"classes":[]},{"id":2538,"url":"https:\/\/www.rbdinstruments.com\/blog\/avc-solenoid-replacement-procedure\/","url_meta":{"origin":647,"position":3},"title":"AVC solenoid replacement procedure","author":"Randy","date":"June 9, 2019","format":false,"excerpt":"This procedure describes how to replace the solenoids in the Auto Valve Controller (AVC) used on Physical Electronics PHI surface analysis systems such as XPS Photo-electron and scanning Auger electron spectrometers. The AVC provides control of the pneumatic valves on the system by using 24V DC solenoids to route air\u2026","rel":"","context":"In &quot;General Optics and Vacuum&quot;","block_context":{"text":"General Optics and Vacuum","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/general-optics-and-vacuum\/"},"img":{"alt_text":"remove screw","src":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/06\/remove-screw.jpg?fit=972%2C648&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/06\/remove-screw.jpg?fit=972%2C648&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/06\/remove-screw.jpg?fit=972%2C648&ssl=1&resize=700%2C400 2x"},"classes":[]},{"id":3720,"url":"https:\/\/www.rbdinstruments.com\/blog\/low-cost-low-cost-molecular-sieve-trap\/","url_meta":{"origin":647,"position":4},"title":"Low Cost Low Cost Molecular Sieve Trap","author":"Randy","date":"April 20, 2023","format":false,"excerpt":"Update 5-28-23 - We tried this on two different pump set ups and it seemed to work well at first. But on one of the set ups the fine mesh O-ring became clogged with small Zeolite pieces and plugged up the line. We removed the Zeolite from that set up,\u2026","rel":"","context":"In &quot;General Optics and Vacuum&quot;","block_context":{"text":"General Optics and Vacuum","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/general-optics-and-vacuum\/"},"img":{"alt_text":"Low Molecular Sieve Trap","src":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2023\/04\/oil-mist-trap.jpg?fit=468%2C468&ssl=1&resize=350%2C200","width":350,"height":200},"classes":[]},{"id":1178,"url":"https:\/\/www.rbdinstruments.com\/blog\/argon-oxygen-xenon-refill-service-phi-systems\/","url_meta":{"origin":647,"position":5},"title":"Argon, Oxygen and Xenon refill service for PHI systems","author":"Randy","date":"July 13, 2014","format":false,"excerpt":"RBD Instruments provides a refill service for the Argon, Oxygen, and Xenon gas bottles that are used with the PHI 04-303 and 06-350 sputter ion guns on many x-ray photoelectron and Auger spectrometers. \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 When you replace the argon or oxygen bottle on your\u2026","rel":"","context":"In &quot;General Optics and Vacuum&quot;","block_context":{"text":"General Optics and Vacuum","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/general-optics-and-vacuum\/"},"img":{"alt_text":"argon-bottle","src":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2014\/07\/argon-bottle.jpg?fit=486%2C324&ssl=1&resize=350%2C200","width":350,"height":200},"classes":[]}],"_links":{"self":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts\/647"}],"collection":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/comments?post=647"}],"version-history":[{"count":1,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts\/647\/revisions"}],"predecessor-version":[{"id":1294,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts\/647\/revisions\/1294"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/media\/648"}],"wp:attachment":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/media?parent=647"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/categories?post=647"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/tags?post=647"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}