{"id":501,"date":"2013-05-01T20:06:36","date_gmt":"2013-05-02T03:06:36","guid":{"rendered":"http:\/\/www.rbdinstruments.com\/blog\/?p=501"},"modified":"2018-11-03T12:59:25","modified_gmt":"2018-11-03T19:59:25","slug":"installing-the-old-style-filaments-in-an-04-500-or-04-548-x-ray-source","status":"publish","type":"post","link":"https:\/\/www.rbdinstruments.com\/blog\/installing-the-old-style-filaments-in-an-04-500-or-04-548-x-ray-source\/","title":{"rendered":"Installing the Old Style Filaments in an 04-500 or 04-548 X-ray Source"},"content":{"rendered":"<p>In my previous two posts about the 04-500 and 04-548 X-ray source I showed you all the steps necessary to completely disassemble and reassemble the source and also how to install the new style filaments.<\/p>\n<p>Old style or new style? If your 04-500 or 04-548 X-ray Source has a white ceramic visible through the outgas holes as shown in the picture below, then you have the \u201cnew style\u201d 622275 X-ray source filament. If you cannot see the white ceramic, then you have the \u201cold style\u201d X-ray source filament.<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/05\/new-style-filament.jpg?ssl=1\"><img data-attachment-id=\"2256\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/installing-the-old-style-filaments-in-an-04-500-or-04-548-x-ray-source\/new-style-filament\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/05\/new-style-filament.jpg?fit=442%2C289&amp;ssl=1\" data-orig-size=\"442,289\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"new style filament\" data-image-description=\"&lt;p&gt;New style filament&lt;\/p&gt;\n\" data-image-caption=\"\" data-medium-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/05\/new-style-filament.jpg?fit=300%2C196&amp;ssl=1\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/05\/new-style-filament.jpg?fit=442%2C289&amp;ssl=1\" decoding=\"async\" loading=\"lazy\" class=\"lazy alignleft size-full wp-image-2256\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/plugins\/jquery-image-lazy-loading\/images\/grey.gif?resize=442%2C289&#038;ssl=1\" data-original=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/05\/new-style-filament.jpg\" alt=\"x-ray_filament\" width=\"442\" height=\"289\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/05\/new-style-filament.jpg?w=442&amp;ssl=1 442w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/05\/new-style-filament.jpg?resize=300%2C196&amp;ssl=1 300w\" sizes=\"(max-width: 442px) 100vw, 442px\" data-recalc-dims=\"1\" \/><noscript><img data-attachment-id=\"2256\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/installing-the-old-style-filaments-in-an-04-500-or-04-548-x-ray-source\/new-style-filament\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/05\/new-style-filament.jpg?fit=442%2C289&amp;ssl=1\" data-orig-size=\"442,289\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"new style filament\" data-image-description=\"&lt;p&gt;New style filament&lt;\/p&gt;\n\" data-image-caption=\"\" data-medium-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/05\/new-style-filament.jpg?fit=300%2C196&amp;ssl=1\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/05\/new-style-filament.jpg?fit=442%2C289&amp;ssl=1\" decoding=\"async\" loading=\"lazy\" class=\"alignleft size-full wp-image-2256\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/05\/new-style-filament.jpg?resize=442%2C289&#038;ssl=1\" alt=\"x-ray_filament\" width=\"442\" height=\"289\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/05\/new-style-filament.jpg?w=442&amp;ssl=1 442w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/05\/new-style-filament.jpg?resize=300%2C196&amp;ssl=1 300w\" sizes=\"(max-width: 442px) 100vw, 442px\" data-recalc-dims=\"1\" \/><\/noscript><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>This post will explain how to install the old style filaments in a 04-500 and 04-548 X-ray source.\u00a0 Refer to the <a href=\"http:\/\/www.youtube.com\/watch?v=j0aLxIsg254\">disassembly<\/a> and <a href=\"http:\/\/www.youtube.com\/watch?v=MZpM64cPac8&amp;feature=plcp\">assembly<\/a> videos for more information on a complete tear down of the source.<\/p>\n<p>The new style filaments comprise a single assembly where the filament posts are brazed into a ceramic base. The old style filaments use a scheme where one end of a coupler connects to the filament wire via a special pointed set screw and slotted ceramic. (A metal tube holds the slotted ceramic in place.) The other end of the coupler connects to the filament post. The coupler needs to be tight and also positioned equidistantly between the molybdenum block and the copper cap. The coupler also needs to be fairly close to the base assembly, but not touching.\u00a0 If you are not careful, it is easy to crack the slotted ceramic that the coupler sits on.<\/p>\n<p>With that background information in mind, let\u2019s go through the steps in the procedure:<\/p>\n<ol>\n<li>Remove the cap from the X-ray source.<\/li>\n<li>Use a tweezers to hold the coupler in place and remove the upper set screws on both couplers (per filament) using an 048-4 \u00a0<a href=\"http:\/\/www.bristolwrench.com\/\">spline<\/a> driver, then remove the old filament.\u00a0 Note that sometimes you just need to replace a broken notched ceramic and the filament may be reusable (if it is not warped or open).<\/li>\n<li>Remove the lower slotted set screw (this is a special set screw with a point on the end of it). Use a tweezers to hold the coupler as you start to loosen the slotted set screw, then hold the set screw as you turn it CCW and remove it from the coupler.<\/li>\n<li>Carefully lift the coupler off of the slotted ceramic.<\/li>\n<\/ol>\n<p>If the slotted ceramic is not cracked it can be reused.\u00a0 Sometimes the copper wire that is inside the ceramic is over-compressed from the pointed set screw. If this is the case, you need to either replace the wire or rotate the wire by 90 degrees so that the tip of the set screw can compress into a fresh section of the wire.<\/p>\n<p>If the slotted ceramic is cracked it needs to be replaced.\u00a0 To replace the slotted ceramic, loosen the set screw in the base about \u00bd turn CCW, which will release the tension on the metal tube. The metal tube does two things \u2013 it protects the long filament ceramic and also provides a mechanism for securing the slotted ceramic. The metal tube has a slot in it that should be positioned perpendicularly to the set screw. When the set screw is tightened, it compresses the metal tube which keeps the slotted ceramic in place.\u00a0 There is a second long filament ceramic that is inside the tube that goes all the way to the filament connector at the other end of the source.<\/p>\n<ol>\n<li>To install a new notched ceramic, straighten the copper wire (it has been compressed by the pointed set screw) so that the new notched ceramic can slide over it. Slide the ceramic over the wire and position it so that the slot is about \u00bc&#8221; above the base and faces the set screw in the base. The end of the metal tube should be flush with the base \u2013 you may need to remove the flange opposite the filament wire feed-through in order to use a pair of needle nose pliers to push the tube up. The slots in the tube need to be perpendicular to the set screw.<\/li>\n<li>Slide the coupler over the notched ceramic and check that the bottom set screw hole is lined up with the hole in the notched ceramic. Loosen the set screw and adjust the height of the coupler by pushing down on the notched ceramic until the bottom of the coupler is about .050&#8243; (or just under 1\/16&#8243;) from the base. Tighten the base set screw. The coupler should be facing roughly parallel with the moly block and be equidistant between the moly block and the inside of the cap. The inside of the cap lines up with the top of the copper tube. Adjust the height and angle of the notched ceramic as necessary.<\/li>\n<li>Check the height of the copper wire; it should be flush with the top of the notched ceramic. Trim if necessary.<\/li>\n<li>Install the slotted pointed set screw into the coupler. Once you get it started, hold the coupler in place with a tweezers so that the coupler is equidistant between the moly block and the top of the copper tube. You need to tighten the set screw until it is holding the coupler firmly in place, so by holding the coupler with a tweezers you can maintain the correct position and also prevent the slotted ceramic from breaking.<\/li>\n<li>Verify that the coupler is in the correct position and that it is solid.<\/li>\n<li>Repeat steps 6 through 9 for the other couplers.<\/li>\n<\/ol>\n<p>Now you are ready to install the filaments.<\/p>\n<ol>\n<li>Carefully slide the filament posts into the couplers.<\/li>\n<li>One side at a time, install the upper set screw and hold the coupler with a tweezers as you tighten the filament.\u00a0 For now, tighten the filaments just a little bit as you may need to make some adjustments to the height.<\/li>\n<li>Repeat steps 1 and 2 for all of the filament posts.<\/li>\n<li>Set the height of the filaments. They should be .030&#8243; below the moly shield. Adjust them as necessary to get the height correct. If they are too low you can raise the couplers if needed, but in general I have found that the couplers need to be pretty close to the base.<\/li>\n<li>Once all of the filament posts are at the correct height, hold the couplers with a tweezers and tighten the filaments firmly.<\/li>\n<li>If the filaments are not parallel to the moly block, hold the couplers with a tweezers and use a needle nose pliers to bend the top, flat part of the filament posts as needed so that the filaments are parallel to the moly block.<\/li>\n<li>When finished, the filaments will be at .030&#8243; below the moly block and parallel to the moly block. The couplers will be firm and equidistant between the moly block and the copper cap.<\/li>\n<\/ol>\n<p>The pictures below will help to clarify the steps provided in the above procedures.\u00a0 Once you have the filaments installed, the system should be baked out. The X-ray source then needs to go through the outgas procedure outlined in the PHI 32-095 manual. With these old style filaments, the more slowly you outgas them the less stress they will put on the couplers and the more reliable the source will be.\u00a0 If you outgas the filaments too quickly they can warp out of position and also stress the couplers, resulting in ghost peaks and possible shorting\/arcing in the X-ray source.<\/p>\n<p>RBD Instruments provides all of the rebuild parts for the 04-500 and 04-548 X-ray sources. You can find those parts on our website at this link:\u00a0 <a href=\"https:\/\/www.rbdinstruments.com\/phi\/optics-parts.html\">RBD Instruments X-ray source parts<\/a><\/p>\n<p class=\"jetpack-slideshow-noscript robots-nocontent\">This slideshow requires JavaScript.<\/p><div id=\"gallery-501-1-slideshow\" class=\"jetpack-slideshow-window jetpack-slideshow jetpack-slideshow-black\" data-trans=\"fade\" data-autostart=\"1\" data-gallery=\"[{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2013\\\/05\\\/04-500-04-548-old-style-filament.jpg?fit=308%2C325\\u0026ssl=1&quot;,&quot;id&quot;:&quot;502&quot;,&quot;title&quot;:&quot;04-500 04-548 old style filament&quot;,&quot;alt&quot;:&quot;04-500 04-548 old style filament&quot;,&quot;caption&quot;:&quot;04-500 04-548 old style filament&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2013\\\/05\\\/couplers-viewed-from-top-of-source.jpg?fit=486%2C324\\u0026ssl=1&quot;,&quot;id&quot;:&quot;504&quot;,&quot;title&quot;:&quot;couplers viewed from top of source&quot;,&quot;alt&quot;:&quot;couplers viewed from top of source&quot;,&quot;caption&quot;:&quot;couplers viewed from top of source&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2013\\\/05\\\/loosen-tube-setscrew.jpg?fit=486%2C324\\u0026ssl=1&quot;,&quot;id&quot;:&quot;507&quot;,&quot;title&quot;:&quot;loosen base set screw&quot;,&quot;alt&quot;:&quot;loosen base set screw&quot;,&quot;caption&quot;:&quot;loosen base set screw&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2013\\\/05\\\/notched-ceramic.jpg?fit=486%2C324\\u0026ssl=1&quot;,&quot;id&quot;:&quot;509&quot;,&quot;title&quot;:&quot;notched ceramic&quot;,&quot;alt&quot;:&quot;notched ceramic&quot;,&quot;caption&quot;:&quot;notched ceramic&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2013\\\/05\\\/notched-ceramic-tube.jpg?fit=324%2C486\\u0026ssl=1&quot;,&quot;id&quot;:&quot;508&quot;,&quot;title&quot;:&quot;notched ceramic tube&quot;,&quot;alt&quot;:&quot;notched ceramic tube&quot;,&quot;caption&quot;:&quot;notched ceramic tube&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2013\\\/05\\\/xray-source-coupler.jpg?fit=486%2C324\\u0026ssl=1&quot;,&quot;id&quot;:&quot;512&quot;,&quot;title&quot;:&quot;xray source coupler&quot;,&quot;alt&quot;:&quot;xray source coupler&quot;,&quot;caption&quot;:&quot;xray source coupler&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2013\\\/05\\\/xray-filament-coupler-set-screws.jpg?fit=584%2C491\\u0026ssl=1&quot;,&quot;id&quot;:&quot;510&quot;,&quot;title&quot;:&quot;xray filament coupler set screws&quot;,&quot;alt&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2013\\\/05\\\/couplers-should-be-equidistant.jpg?fit=594%2C486\\u0026ssl=1&quot;,&quot;id&quot;:&quot;503&quot;,&quot;title&quot;:&quot;couplers should be equidistant&quot;,&quot;alt&quot;:&quot;couplers should be equidistant&quot;,&quot;caption&quot;:&quot;couplers should be equidistant&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2013\\\/05\\\/xray-source-coupler-height.jpg?fit=712%2C491\\u0026ssl=1&quot;,&quot;id&quot;:&quot;511&quot;,&quot;title&quot;:&quot;xray source coupler height&quot;,&quot;alt&quot;:&quot;xray source coupler height&quot;,&quot;caption&quot;:&quot;xray source coupler height&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2013\\\/05\\\/filaments-are-parallel-with-mono-shield.jpg?fit=356%2C246\\u0026ssl=1&quot;,&quot;id&quot;:&quot;505&quot;,&quot;title&quot;:&quot;filaments are parallel with moly shield&quot;,&quot;alt&quot;:&quot;filaments are parallel with moly shield&quot;,&quot;caption&quot;:&quot;filaments are parallel with moly shield&quot;,&quot;itemprop&quot;:&quot;image&quot;}]\" itemscope itemtype=\"https:\/\/schema.org\/ImageGallery\"><\/div>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In my previous two posts about the 04-500 and 04-548 X-ray source I showed you all the steps necessary to completely disassemble and reassemble the source and also how to install the new style filaments. Old style or new style? &hellip; <a href=\"https:\/\/www.rbdinstruments.com\/blog\/installing-the-old-style-filaments-in-an-04-500-or-04-548-x-ray-source\/\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"gallery","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","footnotes":"","jetpack_publicize_message":"","jetpack_is_tweetstorm":false,"jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false}}},"categories":[160],"tags":[71,72,73,70,27],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"","jetpack_shortlink":"https:\/\/wp.me\/p2DEXo-85","jetpack_sharing_enabled":true,"jetpack_likes_enabled":true,"jetpack-related-posts":[{"id":2472,"url":"https:\/\/www.rbdinstruments.com\/blog\/04-500-old-style-x-ray-source-filament-conversion\/","url_meta":{"origin":501,"position":0},"title":"04-500 Old style X-ray source filament conversion","author":"Randy","date":"January 22, 2019","format":false,"excerpt":"The very early PHI 04-500 and 04-548 X-ray sources used a small filament that had couplers to make the connection between the X-ray source and the filament. \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 In addition, the couplers were held in place with a notched ceramic that had\u2026","rel":"","context":"In &quot;General Optics and Vacuum&quot;","block_context":{"text":"General Optics and Vacuum","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/general-optics-and-vacuum\/"},"img":{"alt_text":"old 04-500","src":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/01\/old-04-500.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":147,"url":"https:\/\/www.rbdinstruments.com\/blog\/installing-new-parts-in-a-phi-04-548-or-04-500-x-ray-source-new-style-filaments\/","url_meta":{"origin":501,"position":1},"title":"Installing new parts in a PHI 04-548 or 04-500 X-ray Source: New Style Filaments","author":"Randy","date":"October 6, 2012","format":false,"excerpt":"This procedure and video will explain and show the steps required to reassemble the X-ray source that has the new style filaments. 04-548 Filament Installation Video Refer to this RBD TechSpot blog post for the disassembly procedure and tools required. 04-548 X-ray source reassembly procedure This procedure assumes that you\u2026","rel":"","context":"In &quot;X-ray Sources&quot;","block_context":{"text":"X-ray Sources","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/x-ray-sources\/"},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":130,"url":"https:\/\/www.rbdinstruments.com\/blog\/phi-x-ray-source-filament-replacement\/","url_meta":{"origin":501,"position":2},"title":"Removing the filaments in a PHI 04-548 X-ray Source","author":"Randy","date":"September 25, 2012","format":false,"excerpt":"This is part 1 of 2 - how to completely disassemble the PHI 04-548 X-ray source that has the new style filaments. Part 2 will be how to put it back together with new parts. Here is a link to a video that shows the procedure step by step. New\u2026","rel":"","context":"In &quot;X-ray Sources&quot;","block_context":{"text":"X-ray Sources","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/x-ray-sources\/"},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":1971,"url":"https:\/\/www.rbdinstruments.com\/blog\/x-ray-source-arcing\/","url_meta":{"origin":501,"position":3},"title":"X-ray source arcing","author":"Randy","date":"May 8, 2017","format":false,"excerpt":"X-ray source arcing results in unstable XPS data and can also damage the x-ray source power supply or high voltage control. Typically X-ray source arcing is caused by contamination on the anode, a coated anode support ceramic (the football ceramic) or a loose filament. However one unseen cause of x-ray\u2026","rel":"","context":"In &quot;General Optics and Vacuum&quot;","block_context":{"text":"General Optics and Vacuum","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/general-optics-and-vacuum\/"},"img":{"alt_text":"burnt x-ray source connector","src":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2017\/05\/burnt-x-ray-source-connetor.jpg?fit=972%2C648&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2017\/05\/burnt-x-ray-source-connetor.jpg?fit=972%2C648&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2017\/05\/burnt-x-ray-source-connetor.jpg?fit=972%2C648&ssl=1&resize=700%2C400 2x"},"classes":[]},{"id":1202,"url":"https:\/\/www.rbdinstruments.com\/blog\/phi-15kv-dual-anode-x-ray-source-outgas-procedure\/","url_meta":{"origin":501,"position":4},"title":"PHI 15kV Dual Anode X-ray Source Outgas Procedure","author":"Randy","date":"August 6, 2014","format":false,"excerpt":"This is the procedure that I use to ensure proper outgassing and conditioning of the PHI 04-500 and 04-548 15kV Dual Anode X-ray source after installation or bake-out. It is a slight variation from the procedure in the 32-095 out-gas activate procedure. - Initial Installation After installing the source, the\u2026","rel":"","context":"In &quot;General Optics and Vacuum&quot;","block_context":{"text":"General Optics and Vacuum","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/general-optics-and-vacuum\/"},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":1911,"url":"https:\/\/www.rbdinstruments.com\/blog\/32-095-x-ray-source-control\/","url_meta":{"origin":501,"position":5},"title":"32-095 X-ray source control","author":"Randy","date":"February 28, 2017","format":false,"excerpt":"When the 32-095 X-ray source control is not working properly there are some easy\u00a0 possible solutions that you can check before sending the unit to RBD Instruments Inc. for repair. If the problem is that one filament works but the other one does not, then you should check the fuses\u2026","rel":"","context":"In &quot;General Optics and Vacuum&quot;","block_context":{"text":"General Optics and Vacuum","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/general-optics-and-vacuum\/"},"img":{"alt_text":"32-095 local power supply board +5V","src":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2017\/02\/32-095-local-power-supply-board-+5V.jpg?fit=972%2C648&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2017\/02\/32-095-local-power-supply-board-+5V.jpg?fit=972%2C648&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2017\/02\/32-095-local-power-supply-board-+5V.jpg?fit=972%2C648&ssl=1&resize=700%2C400 2x"},"classes":[]}],"_links":{"self":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts\/501"}],"collection":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/comments?post=501"}],"version-history":[{"count":2,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts\/501\/revisions"}],"predecessor-version":[{"id":2454,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts\/501\/revisions\/2454"}],"wp:attachment":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/media?parent=501"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/categories?post=501"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/tags?post=501"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}