{"id":4195,"date":"2025-05-05T10:24:50","date_gmt":"2025-05-05T17:24:50","guid":{"rendered":"https:\/\/www.rbdinstruments.com\/blog\/?p=4195"},"modified":"2025-05-05T10:24:52","modified_gmt":"2025-05-05T17:24:52","slug":"new-controller-for-ig2-sputter-ion-source-package","status":"publish","type":"post","link":"https:\/\/www.rbdinstruments.com\/blog\/new-controller-for-ig2-sputter-ion-source-package\/","title":{"rendered":"New controller for IG2 sputter ion source package"},"content":{"rendered":"\n<p>The RBD Instrument&#8217;s  IG2 sputter ion source package is a very simple, low cost sputtering package that is based on the old Physical Electronics 04-161\/162 ion source and 20-045 ion source controller. The beam voltage can be varied from 500 volts (lower on request) to 2kV.<\/p>\n\n\n\n<p>There are quite a few of these packages in the field where users do not need anything other than simply sputter cleaning an area off the surface of their specimen. More powerful ion source packages have a variety of performance options and can cost as much as $300K.<\/p>\n\n\n\n<p>Some of the parts needed to build the 32-165 IG2 2 kV ion source controller are no longer available. As a result, we have redesigned the 32-165 and are now providing its replacement, the <strong><a href=\"https:\/\/www.rbdinstruments.com\/products\/ig2.html\" data-type=\"link\" data-id=\"https:\/\/www.rbdinstruments.com\/products\/ig2.html\">32-175<\/a><\/strong>.&nbsp;The 32-175 functionality will be the same as the 32-165 with one exception: we have removed the anode monitor feature and replaced it with an emission current meter. The new emission current meter makes it possible for the user to set the amount of filament current needed to obtain the highest possible ion current and to monitor the thermal stability of the ionizer.&nbsp;Just like the 32-165, the new 32-175 will be compatible with the PHI 04-161 and 04-162 ion sources in addition to the RBD 04-165 2 kV ion source.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?ssl=1\"><img data-attachment-id=\"4196\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/new-controller-for-ig2-sputter-ion-source-package\/32-175-picture\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?fit=1200%2C513&amp;ssl=1\" data-orig-size=\"1200,513\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"32-175-picture\" data-image-description=\"&lt;p&gt;The 32-175 ion source controller is used with the IG2 package and is also compatible with the PHI 04-161\/162 ion sources.&lt;\/p&gt;\n\" data-image-caption=\"&lt;p&gt;32-175 ion source controller&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?fit=300%2C128&amp;ssl=1\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?fit=584%2C250&amp;ssl=1\" decoding=\"async\" loading=\"lazy\" width=\"584\" height=\"250\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/plugins\/jquery-image-lazy-loading\/images\/grey.gif?resize=584%2C250&#038;ssl=1\" data-original=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture-1024x438.jpg\" alt=\"\" class=\"lazy wp-image-4196\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?resize=1024%2C438&amp;ssl=1 1024w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?resize=300%2C128&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?resize=768%2C328&amp;ssl=1 768w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?resize=500%2C214&amp;ssl=1 500w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?w=1200&amp;ssl=1 1200w\" sizes=\"(max-width: 584px) 100vw, 584px\" data-recalc-dims=\"1\" \/><noscript><img data-attachment-id=\"4196\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/new-controller-for-ig2-sputter-ion-source-package\/32-175-picture\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?fit=1200%2C513&amp;ssl=1\" data-orig-size=\"1200,513\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"32-175-picture\" data-image-description=\"&lt;p&gt;The 32-175 ion source controller is used with the IG2 package and is also compatible with the PHI 04-161\/162 ion sources.&lt;\/p&gt;\n\" data-image-caption=\"&lt;p&gt;32-175 ion source controller&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?fit=300%2C128&amp;ssl=1\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?fit=584%2C250&amp;ssl=1\" decoding=\"async\" loading=\"lazy\" width=\"584\" height=\"250\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?resize=584%2C250&#038;ssl=1\" alt=\"\" class=\"wp-image-4196\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?resize=1024%2C438&amp;ssl=1 1024w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?resize=300%2C128&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?resize=768%2C328&amp;ssl=1 768w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?resize=500%2C214&amp;ssl=1 500w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?w=1200&amp;ssl=1 1200w\" sizes=\"(max-width: 584px) 100vw, 584px\" data-recalc-dims=\"1\" \/><\/noscript><\/a><\/figure>\n\n\n\n<p>If you need a low cost sputter ion source visit the RBD Instruments website for more information &#8211;<a href=\"https:\/\/www.rbdinstruments.com\/products\/ig2.html\"> RBD Instruments IG2<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The RBD Instruments 32-175 controller is used with the 04-165 source as part of the IG2 2kV sputter ion source package. <a href=\"https:\/\/www.rbdinstruments.com\/blog\/new-controller-for-ig2-sputter-ion-source-package\/\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":4196,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","footnotes":"","jetpack_publicize_message":"","jetpack_is_tweetstorm":false,"jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false}}},"categories":[161],"tags":[459,460,304,36,458],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2025\/05\/32-175-picture.jpg?fit=1200%2C513&ssl=1","jetpack_shortlink":"https:\/\/wp.me\/p2DEXo-15F","jetpack_sharing_enabled":true,"jetpack_likes_enabled":true,"jetpack-related-posts":[{"id":2839,"url":"https:\/\/www.rbdinstruments.com\/blog\/putting-together-a-compact-uhv-ultra-high-vacuum-chamber-for-spectroscopy\/","url_meta":{"origin":4195,"position":0},"title":"Putting Together a Compact UHV (Ultra-high Vacuum) Chamber for Spectroscopy","author":"Joe Caterinicchio","date":"May 22, 2020","format":false,"excerpt":"Small, inexpensive UHV chambers have been the backbone of many commercial labs and universities for decades. The cost of larger, feature-rich systems has gone up dramatically in recent years, making compact, DIY chambers even more cost-effective for specialized applications and education. RBD has a range of products available to add\u2026","rel":"","context":"In &quot;General Optics and Vacuum&quot;","block_context":{"text":"General Optics and Vacuum","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/general-optics-and-vacuum\/"},"img":{"alt_text":"small vacuum chamber","src":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2020\/05\/chamber-1-bw-cut.png?fit=900%2C1100&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2020\/05\/chamber-1-bw-cut.png?fit=900%2C1100&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2020\/05\/chamber-1-bw-cut.png?fit=900%2C1100&ssl=1&resize=700%2C400 2x"},"classes":[]},{"id":1069,"url":"https:\/\/www.rbdinstruments.com\/blog\/ion-source-filament-assembly-phi-04-303-06-350\/","url_meta":{"origin":4195,"position":1},"title":"Ion source filament assembly for PHI 04-303, 06-350 and FIG 5 ion sources","author":"Randy","date":"May 23, 2014","format":false,"excerpt":"RBD Instruments\u2019 proprietary technique for rebuilding the PHI 04-303 ion gun and 06-350 ion source filament assembly results in more stable sputter rates and longer filament lifetimes than other ionizers. The pictures below are actual 04-303 ion source filament assemblies which show the visible light emitting from the filaments. Note\u2026","rel":"","context":"In &quot;Ion Sources&quot;","block_context":{"text":"Ion Sources","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/ion-sources\/"},"img":{"alt_text":"ion-source-filament","src":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2014\/05\/3-post-ionizer.jpg?fit=640%2C480&ssl=1&resize=350%2C200","width":350,"height":200},"classes":[]},{"id":365,"url":"https:\/\/www.rbdinstruments.com\/blog\/sputter-rate-standard\/","url_meta":{"origin":4195,"position":2},"title":"Sputter rate standard","author":"Randy","date":"June 19, 2019","format":false,"excerpt":"Why do you need sputter rate standards anyway? Each ion source will produce a different sputter rate depending on the conditions that the ion source is operated at, as well as other factors such as the angle of the ion source to the sample. Changing the beam voltage, condenser and\u2026","rel":"","context":"In &quot;Ion Sources&quot;","block_context":{"text":"Ion Sources","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/ion-sources\/"},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":2904,"url":"https:\/\/www.rbdinstruments.com\/blog\/new-ion-beam-profiler\/","url_meta":{"origin":4195,"position":3},"title":"New Ion Beam Profiler","author":"Randy","date":"June 26, 2020","format":false,"excerpt":"This technology is an ion beam profiler that can reconstruct the ion beam intensity in two dimensions with a single measurement device. There are many currently available commercial solutions, but they are overly complicated, require large manipulators that may not fit on existing systems, or require long scan times to\u2026","rel":"","context":"In &quot;General Optics and Vacuum&quot;","block_context":{"text":"General Optics and Vacuum","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/general-optics-and-vacuum\/"},"img":{"alt_text":"RBD IG2 ion gun","src":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2020\/06\/RBD-IG2-ion-gun.jpg?fit=500%2C305&ssl=1&resize=350%2C200","width":350,"height":200},"classes":[]},{"id":371,"url":"https:\/\/www.rbdinstruments.com\/blog\/faraday-cup-procedure-to-align-ion-beam-current\/","url_meta":{"origin":4195,"position":4},"title":"Faraday cup procedure to align ion beam current","author":"Randy","date":"March 11, 2013","format":false,"excerpt":"Using Ta2O5 or SiO2 works well for aligning an ion beam to the focal point of an X-ray photoelectron or scanning Auger electron spectrometer. But, in order to optimize the ion beam focus at larger beam sizes, a Faraday cup is required. The Faraday cup used on many Physical Electronics\/PHI\u2026","rel":"","context":"In &quot;Ion Sources&quot;","block_context":{"text":"Ion Sources","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/ion-sources\/"},"img":{"alt_text":"faraday cup","src":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/03\/faraday-cup-254x300.jpg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":231,"url":"https:\/\/www.rbdinstruments.com\/blog\/how-to-align-the-04-303-ion-gun\/","url_meta":{"origin":4195,"position":5},"title":"How to align the 04-303 ion gun","author":"Randy","date":"November 29, 2012","format":false,"excerpt":"This post explains how to align the Physical Electronics 04-303 ion gun typically found on PHI Auger electron spectroscopy and X-ray photoelectron spectroscopy systems. The alignment principles explained here will apply to just about any surface analysis ion source. First, here is a video that explains all of the alignment\u2026","rel":"","context":"In &quot;Ion Sources&quot;","block_context":{"text":"Ion Sources","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/ion-sources\/"},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]}],"_links":{"self":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts\/4195"}],"collection":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/comments?post=4195"}],"version-history":[{"count":2,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts\/4195\/revisions"}],"predecessor-version":[{"id":4198,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts\/4195\/revisions\/4198"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/media\/4196"}],"wp:attachment":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/media?parent=4195"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/categories?post=4195"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/tags?post=4195"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}