{"id":2605,"date":"2019-09-06T13:34:50","date_gmt":"2019-09-06T20:34:50","guid":{"rendered":"https:\/\/www.rbdinstruments.com\/blog\/?p=2605"},"modified":"2019-09-06T13:39:05","modified_gmt":"2019-09-06T20:39:05","slug":"11-010-electron-gun-control-modification-to-reduce-noise","status":"publish","type":"post","link":"https:\/\/www.rbdinstruments.com\/blog\/11-010-electron-gun-control-modification-to-reduce-noise\/","title":{"rendered":"11-010 Electron Gun Control modification to reduce noise"},"content":{"rendered":"\n<p>Due to aging components, many of the PHI 11-010 5kV electron gun controls have developed a slight noise problem in the emission chopper circuit on the 623 board that results in about 300 mV of 60 hz ripple on the emission voltage, which translates into noise in the electron beam and Auger data.<\/p>\n\n\n\n<p>Since the chopper circuit is never used (it was designed as\na way to get N\/E data with a lock-in recorder), a very simple solution to the\nproblem is to bypass the chopper circuit. <\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure:<\/h2>\n\n\n\n<ol><li>Unplug the 11-010 AC power cord and remove the\ncover.<\/li><li>Solder a jumper between Pins 17 and 18 on the\n623 board as shown below.&nbsp; The 623 board\nis located on the side of the 11-010, just above the filament supply board.<\/li><\/ol>\n\n\n\n<p>This modification will reduce the noise level from about 300 mV to 50 mv or less and results in noticeably cleaner Auger data.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img data-attachment-id=\"2608\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/11-010-electron-gun-control-modification-to-reduce-noise\/11-010-emisson-noise-mod-resistors\/\" data-orig-file=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/11-010-emisson-noise-mod-resistors.bmp\" data-orig-size=\"675,632\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"11-010-emisson-noise-mod-resistors\" data-image-description=\"\" data-image-caption=\"\" data-medium-file=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/11-010-emisson-noise-mod-resistors-300x281.jpg\" data-large-file=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/11-010-emisson-noise-mod-resistors.bmp\" decoding=\"async\" loading=\"lazy\" width=\"584\" height=\"547\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/plugins\/jquery-image-lazy-loading\/images\/grey.gif?resize=584%2C547&#038;ssl=1\" data-original=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/11-010-emisson-noise-mod-resistors.bmp\" alt=\"Chopper board resistors\" class=\"lazy wp-image-2608\" srcset=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/11-010-emisson-noise-mod-resistors.bmp 675w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/11-010-emisson-noise-mod-resistors.bmp?resize=300%2C281&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/11-010-emisson-noise-mod-resistors.bmp?resize=320%2C300&amp;ssl=1 320w\" sizes=\"(max-width: 584px) 100vw, 584px\" data-recalc-dims=\"1\" \/><noscript><img data-attachment-id=\"2608\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/11-010-electron-gun-control-modification-to-reduce-noise\/11-010-emisson-noise-mod-resistors\/\" data-orig-file=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/11-010-emisson-noise-mod-resistors.bmp\" data-orig-size=\"675,632\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"11-010-emisson-noise-mod-resistors\" data-image-description=\"\" data-image-caption=\"\" data-medium-file=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/11-010-emisson-noise-mod-resistors-300x281.jpg\" data-large-file=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/11-010-emisson-noise-mod-resistors.bmp\" decoding=\"async\" loading=\"lazy\" width=\"675\" height=\"632\" src=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/11-010-emisson-noise-mod-resistors.bmp\" alt=\"Chopper board resistors\" class=\"wp-image-2608\" srcset=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/11-010-emisson-noise-mod-resistors.bmp 675w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/11-010-emisson-noise-mod-resistors.bmp?resize=300%2C281&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/11-010-emisson-noise-mod-resistors.bmp?resize=320%2C300&amp;ssl=1 320w\" sizes=\"(max-width: 584px) 100vw, 584px\" \/><\/noscript><figcaption>This jumper will bypass the Chopper board circuitry<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img data-attachment-id=\"2606\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/11-010-electron-gun-control-modification-to-reduce-noise\/623-board\/\" data-orig-file=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/623-board.bmp\" data-orig-size=\"675,456\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"623-board\" data-image-description=\"\" data-image-caption=\"\" data-medium-file=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/623-board-300x203.jpg\" data-large-file=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/623-board.bmp\" decoding=\"async\" loading=\"lazy\" width=\"584\" height=\"395\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/plugins\/jquery-image-lazy-loading\/images\/grey.gif?resize=584%2C395&#038;ssl=1\" data-original=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/623-board.bmp\" alt=\"Chopper board schematic\" class=\"lazy wp-image-2606\" srcset=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/623-board.bmp 675w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/623-board.bmp?resize=300%2C203&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/623-board.bmp?resize=444%2C300&amp;ssl=1 444w\" sizes=\"(max-width: 584px) 100vw, 584px\" data-recalc-dims=\"1\" \/><noscript><img data-attachment-id=\"2606\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/11-010-electron-gun-control-modification-to-reduce-noise\/623-board\/\" data-orig-file=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/623-board.bmp\" data-orig-size=\"675,456\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"623-board\" data-image-description=\"\" data-image-caption=\"\" data-medium-file=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/623-board-300x203.jpg\" data-large-file=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/623-board.bmp\" decoding=\"async\" loading=\"lazy\" width=\"675\" height=\"456\" src=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/623-board.bmp\" alt=\"Chopper board schematic\" class=\"wp-image-2606\" srcset=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/623-board.bmp 675w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/623-board.bmp?resize=300%2C203&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/623-board.bmp?resize=444%2C300&amp;ssl=1 444w\" sizes=\"(max-width: 584px) 100vw, 584px\" \/><\/noscript><figcaption>Jumper location on Chopper board<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"lazy \" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/plugins\/jquery-image-lazy-loading\/images\/grey.gif?w=584&#038;ssl=1\" data-original=\"blob:https:\/\/www.rbdinstruments.com\/2543286f-a56f-4a9e-93e1-dc9d5fc8fea8\" alt=\"\" data-recalc-dims=\"1\"\/><noscript><img decoding=\"async\" src=\"blob:https:\/\/www.rbdinstruments.com\/2543286f-a56f-4a9e-93e1-dc9d5fc8fea8\" alt=\"\"\/><\/noscript><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Due to aging components, many of the PHI 11-010 5kV electron gun controls have developed a slight noise problem in the emission chopper circuit on the 623 board that results in about 300 mV of 60 hz ripple on the &hellip; <a href=\"https:\/\/www.rbdinstruments.com\/blog\/11-010-electron-gun-control-modification-to-reduce-noise\/\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":2608,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","footnotes":"","jetpack_publicize_message":"","jetpack_is_tweetstorm":false,"jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false}}},"categories":[162],"tags":[150,151],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2019\/09\/11-010-emisson-noise-mod-resistors.bmp","jetpack_shortlink":"https:\/\/wp.me\/p2DEXo-G1","jetpack_sharing_enabled":true,"jetpack_likes_enabled":true,"jetpack-related-posts":[{"id":1205,"url":"https:\/\/www.rbdinstruments.com\/blog\/11-010-electron-gun-control-operation-repair-info\/","url_meta":{"origin":2605,"position":0},"title":"11-010 electron gun control operation and repair info","author":"Randy","date":"August 9, 2014","format":false,"excerpt":"This post is a compilation of information that we have provided in some of our newsletters about the Physical Electronics 11-010 electron gun control. These units are typically found with the 10-150\/155 and 15-255G CMA auger and double pass x-ray photoelectron analyzers. As always, refer servicing to personnel trained to\u2026","rel":"","context":"In &quot;Operation and Calibration Procedures&quot;","block_context":{"text":"Operation and Calibration Procedures","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/operation-and-calibration-procedures\/"},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":1452,"url":"https:\/\/www.rbdinstruments.com\/blog\/15-255g-filament-change-procedure\/","url_meta":{"origin":2605,"position":1},"title":"15-255G Filament Change Procedure","author":"Randy","date":"May 9, 2015","format":false,"excerpt":"This post explains how to replace the C75-010 tungsten filament used in the Physical Electronics 15-255G double pass CMA.\u00a0\u00a0\u00a0 Refer to the pictures below for more details.\u00a0 RBD Instruments provides the C75-010 filaments as well as any other parts that you may need for your 15-255G analyzer.\u00a0 We also offer\u2026","rel":"","context":"In &quot;General Optics and Vacuum&quot;","block_context":{"text":"General Optics and Vacuum","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/general-optics-and-vacuum\/"},"img":{"alt_text":"check-screw-distance","src":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2015\/05\/check-screw-distance.jpg?fit=486%2C324&ssl=1&resize=350%2C200","width":350,"height":200},"classes":[]},{"id":345,"url":"https:\/\/www.rbdinstruments.com\/blog\/ion-beam-induced-low-energy-electrons\/","url_meta":{"origin":2605,"position":2},"title":"Ion Beam Induced Low Energy Electrons","author":"Randy","date":"February 6, 2013","format":false,"excerpt":"For the purpose of checking the performance of a surface analysis spectrometer such as a cylindrical mirror analyzer (CMA) or spherical capacitive analyzer (SCA), looking at an ion induced low energy electron peak can be extremely helpful. The peak typically occurs at about 20 to 50 eV and the size\u2026","rel":"","context":"In &quot;Operation and Calibration Procedures&quot;","block_context":{"text":"Operation and Calibration Procedures","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/operation-and-calibration-procedures\/"},"img":{"alt_text":"ion gun noise","src":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/02\/Ion-gun-noise.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":707,"url":"https:\/\/www.rbdinstruments.com\/blog\/10-155-filament-replacement-procedure\/","url_meta":{"origin":2605,"position":3},"title":"10-155 Filament replacement procedure","author":"Randy","date":"July 22, 2013","format":false,"excerpt":"This blog post is an updated version of the 10-155 filament replacement procedure first published on the RBD Instruments website as a Technical Tip a number of years ago. This version has been updated with some close up pictures of the electron gun assembly shown at the bottom of this\u2026","rel":"","context":"In &quot;General Optics and Vacuum&quot;","block_context":{"text":"General Optics and Vacuum","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/general-optics-and-vacuum\/"},"img":{"alt_text":"filament-coupler-space-between","src":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/07\/filament-coupler-space.jpg?fit=972%2C648&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/07\/filament-coupler-space.jpg?fit=972%2C648&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2013\/07\/filament-coupler-space.jpg?fit=972%2C648&ssl=1&resize=700%2C400 2x"},"classes":[]},{"id":1794,"url":"https:\/\/www.rbdinstruments.com\/blog\/obsolete-phi-units\/","url_meta":{"origin":2605,"position":4},"title":"Obsolete PHI units","author":"Randy","date":"July 25, 2016","format":false,"excerpt":"Obsolete PHI units As many of you may know, RBD Instruments has been providing repair services and parts for old Physical Electronics (PHI) surface analysis systems and components for over 26 years. In fact, some of the electronic and optic units that we work on are over 45 years old!\u2026","rel":"","context":"In &quot;Miscellaneous&quot;","block_context":{"text":"Miscellaneous","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/miscellaneous\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/07\/surface-analysis.png?fit=225%2C225&ssl=1&resize=350%2C200","width":350,"height":200},"classes":[]},{"id":1591,"url":"https:\/\/www.rbdinstruments.com\/blog\/parts-that-fail-in-older-phi-electronic-units\/","url_meta":{"origin":2605,"position":5},"title":"Parts that fail in older PHI electronic units","author":"Randy","date":"October 31, 2015","format":false,"excerpt":"Common parts that fail in various older PHI electronic units This post lists common parts that fail in various PHI electronic units such as electron gun controls, analyzer controls and electron multiplier supplies. The part designations show an example of where a partial part may be used in a control.\u2026","rel":"","context":"In &quot;Operation and Calibration Procedures&quot;","block_context":{"text":"Operation and Calibration Procedures","link":"https:\/\/www.rbdinstruments.com\/blog\/category\/operation-and-calibration-procedures\/"},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]}],"_links":{"self":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts\/2605"}],"collection":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/comments?post=2605"}],"version-history":[{"count":3,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts\/2605\/revisions"}],"predecessor-version":[{"id":2615,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts\/2605\/revisions\/2615"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/media\/2608"}],"wp:attachment":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/media?parent=2605"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/categories?post=2605"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/tags?post=2605"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}