{"id":1750,"date":"2016-05-08T19:48:11","date_gmt":"2016-05-09T02:48:11","guid":{"rendered":"http:\/\/www.rbdinstruments.com\/blog\/?p=1750"},"modified":"2020-12-14T08:51:20","modified_gmt":"2020-12-14T16:51:20","slug":"high-voltage-connector-types","status":"publish","type":"post","link":"https:\/\/www.rbdinstruments.com\/blog\/high-voltage-connector-types\/","title":{"rendered":"High voltage connector types"},"content":{"rendered":"<p><del><\/del>There are primarily five different high voltage connectors that are used on surface analysis systems. This post will explain the differences between them and provide information on how to connect them.<\/p>\n<p>The high voltage connector types are:<\/p>\n<p>BNC<\/p>\n<p>MHV<\/p>\n<p>SHV<\/p>\n<p>10kV SHV<\/p>\n<p>20kV RF<\/p>\n<div id=\"attachment_1758\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/BNC_connector.jpg?ssl=1\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1758\" data-attachment-id=\"1758\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/high-voltage-connector-types\/bnc_connector\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/BNC_connector.jpg?fit=566%2C475&amp;ssl=1\" data-orig-size=\"566,475\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"BNC_connector\" data-image-description=\"&lt;p&gt;BNC_connector&lt;\/p&gt;\n\" data-image-caption=\"&lt;p&gt;BNC_connector&lt;\/p&gt;\n\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/BNC_connector.jpg?fit=566%2C475&amp;ssl=1\" class=\"lazy size-medium wp-image-1758\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/plugins\/jquery-image-lazy-loading\/images\/grey.gif?resize=300%2C251&#038;ssl=1\" data-original=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/BNC_connector-300x251.jpg\" alt=\"BNC_connector\" width=\"300\" height=\"251\" \/><p id=\"caption-attachment-1758\" class=\"wp-caption-text\"><noscript><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"1758\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/high-voltage-connector-types\/bnc_connector\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/BNC_connector.jpg?fit=566%2C475&amp;ssl=1\" data-orig-size=\"566,475\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"BNC_connector\" data-image-description=\"&lt;p&gt;BNC_connector&lt;\/p&gt;\n\" data-image-caption=\"&lt;p&gt;BNC_connector&lt;\/p&gt;\n\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/BNC_connector.jpg?fit=566%2C475&amp;ssl=1\" class=\"size-medium wp-image-1758\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/BNC_connector.jpg?resize=300%2C251&#038;ssl=1\" alt=\"BNC_connector\" width=\"300\" height=\"251\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/BNC_connector.jpg?resize=300%2C251&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/BNC_connector.jpg?resize=357%2C300&amp;ssl=1 357w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/BNC_connector.jpg?w=566&amp;ssl=1 566w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/noscript><\/a> BNC_connector<\/p><\/div>\n<p>This connector is not really considered a high voltage connector as it is only rated to 600V DC, but it is found most surface analysis systems on the specimen stage as the target connector.<\/p>\n<div id=\"attachment_1760\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/MHV_cable_connector.jpg?ssl=1\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1760\" data-attachment-id=\"1760\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/high-voltage-connector-types\/mhv_cable_connector\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/MHV_cable_connector.jpg?fit=1685%2C1625&amp;ssl=1\" data-orig-size=\"1685,1625\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"MHV_cable_connector\" data-image-description=\"&lt;p&gt;MHV_cable_connector&lt;\/p&gt;\n\" data-image-caption=\"&lt;p&gt;MHV_cable_connector&lt;\/p&gt;\n\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/MHV_cable_connector.jpg?fit=584%2C563&amp;ssl=1\" class=\"lazy size-medium wp-image-1760\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/plugins\/jquery-image-lazy-loading\/images\/grey.gif?resize=300%2C289&#038;ssl=1\" data-original=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/MHV_cable_connector-300x289.jpg\" alt=\"MHV_cable_connector\" width=\"300\" height=\"289\" \/><p id=\"caption-attachment-1760\" class=\"wp-caption-text\"><noscript><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"1760\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/high-voltage-connector-types\/mhv_cable_connector\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/MHV_cable_connector.jpg?fit=1685%2C1625&amp;ssl=1\" data-orig-size=\"1685,1625\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"MHV_cable_connector\" data-image-description=\"&lt;p&gt;MHV_cable_connector&lt;\/p&gt;\n\" data-image-caption=\"&lt;p&gt;MHV_cable_connector&lt;\/p&gt;\n\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/MHV_cable_connector.jpg?fit=584%2C563&amp;ssl=1\" class=\"size-medium wp-image-1760\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/MHV_cable_connector.jpg?resize=300%2C289&#038;ssl=1\" alt=\"MHV_cable_connector\" width=\"300\" height=\"289\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/MHV_cable_connector.jpg?resize=300%2C289&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/MHV_cable_connector.jpg?resize=1024%2C987&amp;ssl=1 1024w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/MHV_cable_connector.jpg?resize=311%2C300&amp;ssl=1 311w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/MHV_cable_connector.jpg?w=1685&amp;ssl=1 1685w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/MHV_cable_connector.jpg?w=1168&amp;ssl=1 1168w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/noscript><\/a> MHV_cable_connector<\/p><\/div>\n<p>The MHV connector looks similar to a BNC but it is slightly deeper and it has slightly protruding insulation on the make plug. MHV stands for miniature high voltage and this connector type is rated for up to 5kV and 3 amps. The MHV connector is common on older surface analysis components but it is not considered safe by today\u2019s standards as it is possible to touch the male pin with a finger and get shocked. It is also possible to force a BNC cable onto a MHV connector.<\/p>\n<p>Newer surface analysis components use the SHV (safe high voltage connector) which is rated at 5kV and 5 amps.<\/p>\n<div id=\"attachment_1763\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/SHV_connector.jpg?ssl=1\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1763\" data-attachment-id=\"1763\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/high-voltage-connector-types\/shv_connector\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/SHV_connector.jpg?fit=1357%2C989&amp;ssl=1\" data-orig-size=\"1357,989\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"SHV_connector\" data-image-description=\"&lt;p&gt;SHV_connector&lt;\/p&gt;\n\" data-image-caption=\"&lt;p&gt;SHV_connector&lt;\/p&gt;\n\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/SHV_connector.jpg?fit=584%2C425&amp;ssl=1\" class=\"lazy size-medium wp-image-1763\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/plugins\/jquery-image-lazy-loading\/images\/grey.gif?resize=300%2C218&#038;ssl=1\" data-original=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/SHV_connector-300x218.jpg\" alt=\"SHV_connector\" width=\"300\" height=\"218\" \/><p id=\"caption-attachment-1763\" class=\"wp-caption-text\"><noscript><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"1763\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/high-voltage-connector-types\/shv_connector\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/SHV_connector.jpg?fit=1357%2C989&amp;ssl=1\" data-orig-size=\"1357,989\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"SHV_connector\" data-image-description=\"&lt;p&gt;SHV_connector&lt;\/p&gt;\n\" data-image-caption=\"&lt;p&gt;SHV_connector&lt;\/p&gt;\n\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/SHV_connector.jpg?fit=584%2C425&amp;ssl=1\" class=\"size-medium wp-image-1763\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/SHV_connector.jpg?resize=300%2C218&#038;ssl=1\" alt=\"SHV_connector\" width=\"300\" height=\"218\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/SHV_connector.jpg?resize=300%2C218&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/SHV_connector.jpg?resize=1024%2C746&amp;ssl=1 1024w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/SHV_connector.jpg?resize=411%2C300&amp;ssl=1 411w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/SHV_connector.jpg?w=1357&amp;ssl=1 1357w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/SHV_connector.jpg?w=1168&amp;ssl=1 1168w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/noscript><\/a> SHV_connector<\/p><\/div>\n<p>The SHV has a recessed male pin and so it is not possible to touch the pin with a finger. The dimensions of the SHV connector make it impossible to connect it to a BNC or MHV connector. It is also designed so that the HV contact is broken before the ground contact when removing the cable.<\/p>\n<div id=\"attachment_1751\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/10kV_SHV_connector.jpg?ssl=1\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1751\" data-attachment-id=\"1751\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/high-voltage-connector-types\/10kv_shv_connector\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/10kV_SHV_connector.jpg?fit=672%2C536&amp;ssl=1\" data-orig-size=\"672,536\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"10kV_SHV_connector\" data-image-description=\"&lt;p&gt;10kV_SHV_connector&lt;\/p&gt;\n\" data-image-caption=\"&lt;p&gt;10kV_SHV_connector&lt;\/p&gt;\n\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/10kV_SHV_connector.jpg?fit=584%2C466&amp;ssl=1\" class=\"lazy size-medium wp-image-1751\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/plugins\/jquery-image-lazy-loading\/images\/grey.gif?resize=300%2C239&#038;ssl=1\" data-original=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/10kV_SHV_connector-300x239.jpg\" alt=\"10kV_SHV_connector\" width=\"300\" height=\"239\" \/><p id=\"caption-attachment-1751\" class=\"wp-caption-text\"><noscript><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"1751\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/high-voltage-connector-types\/10kv_shv_connector\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/10kV_SHV_connector.jpg?fit=672%2C536&amp;ssl=1\" data-orig-size=\"672,536\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"10kV_SHV_connector\" data-image-description=\"&lt;p&gt;10kV_SHV_connector&lt;\/p&gt;\n\" data-image-caption=\"&lt;p&gt;10kV_SHV_connector&lt;\/p&gt;\n\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/10kV_SHV_connector.jpg?fit=584%2C466&amp;ssl=1\" class=\"size-medium wp-image-1751\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/10kV_SHV_connector.jpg?resize=300%2C239&#038;ssl=1\" alt=\"10kV_SHV_connector\" width=\"300\" height=\"239\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/10kV_SHV_connector.jpg?resize=300%2C239&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/10kV_SHV_connector.jpg?resize=376%2C300&amp;ssl=1 376w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/10kV_SHV_connector.jpg?w=672&amp;ssl=1 672w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/noscript><\/a> 10kV_SHV_connector<\/p><\/div>\n<p>For higher voltages on components such as ion pump controllers the next voltage rating is the 10kV SHV connector.<\/p>\n<p>The 10kV SHV connector is considerably larger than the 5kV SHV connector but is shares features such as the recessed pins.<\/p>\n<div id=\"attachment_1754\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/20kV_SHV_connector.jpg?ssl=1\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1754\" data-attachment-id=\"1754\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/high-voltage-connector-types\/20kv_shv_connector\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/20kV_SHV_connector.jpg?fit=584%2C444&amp;ssl=1\" data-orig-size=\"584,444\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"20kV_SHV_connector\" data-image-description=\"&lt;p&gt;20kV_SHV_connector&lt;\/p&gt;\n\" data-image-caption=\"&lt;p&gt;20kV_SHV_connector&lt;\/p&gt;\n\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/20kV_SHV_connector.jpg?fit=584%2C444&amp;ssl=1\" class=\"lazy size-medium wp-image-1754\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/plugins\/jquery-image-lazy-loading\/images\/grey.gif?resize=300%2C228&#038;ssl=1\" data-original=\"https:\/\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/20kV_SHV_connector-300x228.jpg\" alt=\"20kV_SHV_connector\" width=\"300\" height=\"228\" \/><p id=\"caption-attachment-1754\" class=\"wp-caption-text\"><noscript><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"1754\" data-permalink=\"https:\/\/www.rbdinstruments.com\/blog\/high-voltage-connector-types\/20kv_shv_connector\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/20kV_SHV_connector.jpg?fit=584%2C444&amp;ssl=1\" data-orig-size=\"584,444\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"20kV_SHV_connector\" data-image-description=\"&lt;p&gt;20kV_SHV_connector&lt;\/p&gt;\n\" data-image-caption=\"&lt;p&gt;20kV_SHV_connector&lt;\/p&gt;\n\" data-large-file=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/20kV_SHV_connector.jpg?fit=584%2C444&amp;ssl=1\" class=\"size-medium wp-image-1754\" src=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/20kV_SHV_connector.jpg?resize=300%2C228&#038;ssl=1\" alt=\"20kV_SHV_connector\" width=\"300\" height=\"228\" srcset=\"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/20kV_SHV_connector.jpg?resize=300%2C228&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/20kV_SHV_connector.jpg?resize=394%2C300&amp;ssl=1 394w, https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/20kV_SHV_connector.jpg?w=584&amp;ssl=1 584w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/noscript><\/a> 20kV_SHV_connector<\/p><\/div>\n<p>Finally, the 20kV RF connector is used on components such at 15kV dual anode x-ray sources. It is very similar to the 10kV SHV connector only larger.<\/p>\n<p>All of these connectors need special crimp tools to attach them to cables.<\/p>\n<p>Below are useful links for each connector type that include dimensions and assembly instructions:<\/p>\n<p><a href=\"https:\/\/www.cableorganizer.com\/learning-center\/how-to\/how-to-attach-a-crimp-on-bnc-connector.html\">BNC<\/a><\/p>\n<p><a href=\"https:\/\/www.google.com\/url?sa=t&amp;rct=j&amp;q=&amp;esrc=s&amp;source=web&amp;cd=3&amp;cad=rja&amp;uact=8&amp;ved=0ahUKEwi9gt3P9MvMAhVQ9GMKHdcpCekQFggtMAI&amp;url=http%3A%2F%2Fwww.solidsealing.com%2Ftechnical%2Fdocuments%2FNS10550.pdf&amp;usg=AFQjCNGezwagaw9c5NePOOLmORFd5qSvBQ&amp;sig2=XWc70qfihAyWb-2hAIzisA&amp;bvm=bv.121421273,d.cGc\">MHV<\/a><\/p>\n<p><a href=\"https:\/\/www.google.com\/url?sa=t&amp;rct=j&amp;q=&amp;esrc=s&amp;source=web&amp;cd=1&amp;cad=rja&amp;uact=8&amp;ved=0ahUKEwi2pMjj9MvMAhVJ-GMKHcJiBZkQFggmMAA&amp;url=http%3A%2F%2Fwww.solidsealing.com%2Ftechnical%2Fdocuments%2FNS10544.pdf&amp;usg=AFQjCNGhLlB1O-IOu19rBkwyMHzQFI44jw&amp;sig2=jMtbBKtq4SF-zRRub2-eTQ\">SHV<\/a><\/p>\n<p><a href=\"https:\/\/www.google.com\/url?sa=t&amp;rct=j&amp;q=&amp;esrc=s&amp;source=web&amp;cd=2&amp;cad=rja&amp;uact=8&amp;ved=0ahUKEwiu5tOL48vMAhUCyWMKHemrBq4QFggrMAE&amp;url=http%3A%2F%2Fwww.solidsealing.com%2Ftechnical%2Fdocuments%2FNS10548.pdf&amp;usg=AFQjCNHdrkxqS7FZrpMH4vqIFoCGuWsVlg&amp;sig2=eA2orzwCRavGdFUCJwFSHQ&amp;bvm=bv.121421273,d.cGc\">10kV SHV<\/a><\/p>\n<p><a href=\"https:\/\/www.google.com\/url?sa=t&amp;rct=j&amp;q=&amp;esrc=s&amp;source=web&amp;cd=3&amp;cad=rja&amp;uact=8&amp;ved=0ahUKEwi2pMjj9MvMAhVJ-GMKHcJiBZkQFgg0MAI&amp;url=http%3A%2F%2Fwww.solidsealing.com%2Ftechnical%2Fdocuments%2FNS10549.pdf&amp;usg=AFQjCNERLIF1vpy1drP2K25LmIn3fP5alA&amp;sig2=VC98rUGaUH07IIEwaxmXPg\">20kV RF<\/a><\/p>\n<p class=\"jetpack-slideshow-noscript robots-nocontent\">This slideshow requires JavaScript.<\/p><div id=\"gallery-1750-1-slideshow\" class=\"jetpack-slideshow-window jetpack-slideshow jetpack-slideshow-black\" data-trans=\"fade\" data-autostart=\"1\" data-gallery=\"[{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/SHV_connector_side_view.jpg?fit=2337%2C1305\\u0026ssl=1&quot;,&quot;id&quot;:&quot;1764&quot;,&quot;title&quot;:&quot;SHV_connector_side_view&quot;,&quot;alt&quot;:&quot;SHV_connector_side_view&quot;,&quot;caption&quot;:&quot;SHV_connector_side_view&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/20kV_SHV_connector_side_view.jpg?fit=972%2C648\\u0026ssl=1&quot;,&quot;id&quot;:&quot;1756&quot;,&quot;title&quot;:&quot;20kV_SHV_connector_side_view&quot;,&quot;alt&quot;:&quot;20kV_SHV_connector_side_view&quot;,&quot;caption&quot;:&quot;20kV_SHV_connector_side_view&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/SHV_connector.jpg?fit=1357%2C989\\u0026ssl=1&quot;,&quot;id&quot;:&quot;1763&quot;,&quot;title&quot;:&quot;SHV_connector&quot;,&quot;alt&quot;:&quot;SHV_connector&quot;,&quot;caption&quot;:&quot;SHV_connector&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/MHV_vacuum_connector.jpg?fit=972%2C648\\u0026ssl=1&quot;,&quot;id&quot;:&quot;1762&quot;,&quot;title&quot;:&quot;MHV_vacuum_connector&quot;,&quot;alt&quot;:&quot;MHV_vacuum_connector&quot;,&quot;caption&quot;:&quot;MHV_vacuum_connector&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/BNC_connector.jpg?fit=566%2C475\\u0026ssl=1&quot;,&quot;id&quot;:&quot;1758&quot;,&quot;title&quot;:&quot;BNC_connector&quot;,&quot;alt&quot;:&quot;BNC_connector&quot;,&quot;caption&quot;:&quot;BNC_connector&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/BNC_connector_side_view.jpg?fit=2673%2C1977\\u0026ssl=1&quot;,&quot;id&quot;:&quot;1759&quot;,&quot;title&quot;:&quot;BNC_connector_side_view&quot;,&quot;alt&quot;:&quot;BNC_connector_side_view&quot;,&quot;caption&quot;:&quot;BNC_connector_side_view&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/10kV_SHV_connector_side_view.jpg?fit=2517%2C1633\\u0026ssl=1&quot;,&quot;id&quot;:&quot;1753&quot;,&quot;title&quot;:&quot;10kV_SHV_connector_side_view&quot;,&quot;alt&quot;:&quot;10kV_SHV_connector_side_view&quot;,&quot;caption&quot;:&quot;10kV_SHV_connector_side_view&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/BNC_chassis_mount_connector.jpg?fit=972%2C648\\u0026ssl=1&quot;,&quot;id&quot;:&quot;1757&quot;,&quot;title&quot;:&quot;BNC_chassis_mount_connector&quot;,&quot;alt&quot;:&quot;BNC_chassis_mount_connector&quot;,&quot;caption&quot;:&quot;BNC_chassis_mount_connector&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/10kV_SHV_connector.jpg?fit=672%2C536\\u0026ssl=1&quot;,&quot;id&quot;:&quot;1751&quot;,&quot;title&quot;:&quot;10kV_SHV_connector&quot;,&quot;alt&quot;:&quot;10kV_SHV_connector&quot;,&quot;caption&quot;:&quot;10kV_SHV_connector&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/MHV_cable_connector_side_view.jpg?fit=972%2C648\\u0026ssl=1&quot;,&quot;id&quot;:&quot;1761&quot;,&quot;title&quot;:&quot;MHV_cable_connector_side_view&quot;,&quot;alt&quot;:&quot;MHV_cable_connector_side_view&quot;,&quot;caption&quot;:&quot;MHV_cable_connector_side_view&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/SHV_vacuum_connector.jpg?fit=972%2C648\\u0026ssl=1&quot;,&quot;id&quot;:&quot;1765&quot;,&quot;title&quot;:&quot;SHV_vacuum_connector&quot;,&quot;alt&quot;:&quot;SHV_vacuum_connector&quot;,&quot;caption&quot;:&quot;SHV_vacuum_connector&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/MHV_cable_connector.jpg?fit=1685%2C1625\\u0026ssl=1&quot;,&quot;id&quot;:&quot;1760&quot;,&quot;title&quot;:&quot;MHV_cable_connector&quot;,&quot;alt&quot;:&quot;MHV_cable_connector&quot;,&quot;caption&quot;:&quot;MHV_cable_connector&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/10kV_SHV_connector_chassis_connector.jpg?fit=972%2C648\\u0026ssl=1&quot;,&quot;id&quot;:&quot;1752&quot;,&quot;title&quot;:&quot;10kV_SHV_connector_chassis_connector&quot;,&quot;alt&quot;:&quot;10kV_SHV_connector_chassis_connector&quot;,&quot;caption&quot;:&quot;10kV_SHV_connector_chassis_connector&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/20kV_SHV_connector.jpg?fit=584%2C444\\u0026ssl=1&quot;,&quot;id&quot;:&quot;1754&quot;,&quot;title&quot;:&quot;20kV_SHV_connector&quot;,&quot;alt&quot;:&quot;20kV_SHV_connector&quot;,&quot;caption&quot;:&quot;20kV_SHV_connector&quot;,&quot;itemprop&quot;:&quot;image&quot;},{&quot;src&quot;:&quot;https:\\\/\\\/i0.wp.com\\\/www.rbdinstruments.com\\\/blog\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/20kV_SHV_connector_chassis_mount.jpg?fit=972%2C648\\u0026ssl=1&quot;,&quot;id&quot;:&quot;1755&quot;,&quot;title&quot;:&quot;20kV_SHV_connector_chassis_mount&quot;,&quot;alt&quot;:&quot;20kV_SHV_connector_chassis_mount&quot;,&quot;caption&quot;:&quot;20kV_SHV_connector_chassis_mount&quot;,&quot;itemprop&quot;:&quot;image&quot;}]\" itemscope itemtype=\"https:\/\/schema.org\/ImageGallery\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>There are primarily five different high voltage connectors that are used on surface analysis systems. This post will explain the differences between them and provide information on how to connect them. The high voltage connector types are: BNC MHV SHV &hellip; <a href=\"https:\/\/www.rbdinstruments.com\/blog\/high-voltage-connector-types\/\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":1763,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[164],"tags":[218,219,217,216],"class_list":["post-1750","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general-optics-and-vacuum","tag-10kv-shv","tag-20kv-rf","tag-mhv","tag-shv"],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/i0.wp.com\/www.rbdinstruments.com\/blog\/wp-content\/uploads\/2016\/05\/SHV_connector.jpg?fit=1357%2C989&ssl=1","jetpack_shortlink":"https:\/\/wp.me\/p2DEXo-se","jetpack_sharing_enabled":true,"jetpack_likes_enabled":true,"jetpack-related-posts":[],"_links":{"self":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts\/1750","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/comments?post=1750"}],"version-history":[{"count":1,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts\/1750\/revisions"}],"predecessor-version":[{"id":3060,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/posts\/1750\/revisions\/3060"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/media\/1763"}],"wp:attachment":[{"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/media?parent=1750"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/categories?post=1750"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rbdinstruments.com\/blog\/wp-json\/wp\/v2\/tags?post=1750"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}